        CLX-2DIM2

        2 Channel Dimmer Module, 2 Feeds.

        Discontinued

        This product has been discontinued. Please contact Crestron True Blue Support at 1-888-CRESTRON for a replacement solution or more information.

        Please see the CLX-2DIM8 for an alternative dimmer module with two feeds.

         

         

        As part of a complete Crestron lighting system, the CLX-2DIM2 lighting control module provides 2 independent channels of dimming for incandescent, magnetic low-voltage, neon/cold cathode, and dimmable 2-wire fluorescent loads. Each channel is rated for 1920 Watts, with a total module rating of 3840 Watts when fed from two separate 20 Amp feeds. Air-gap relays are provided on each channel output allowing an individual circuit to be serviced without disabling the entire module.
        Visit the Crestron® Lighting Fixture Compatibility page to find out which Crestron lighting devices have been tested and are compatible with third party lighting fixtures.

        Please see the CLX-2DIM8 for an alternative dimmer module with two feeds.

         

        As part of a complete Crestron lighting system, the CLX-2DIM2 lighting control module provides 2 independent channels of dimming for incandescent, magnetic low-voltage, neon/cold cathode, and dimmable 2-wire fluorescent loads. Each channel is rated for 1920 Watts, with a total module rating of 3840 Watts when fed from two separate 20 Amp feeds. Air-gap relays are provided on each channel output allowing an individual circuit to be serviced without disabling the entire module.

        CLX-Series dimmers are rigorously built using 40 Amp triacs and oversized heat sinks for ultimate reliability. Split-bobbin transformers and ground referenced electronics deliver superior performance. Lamp flicker is minimized through Crestron's innovative zero-crossing detection technique backed by proprietary firmware. Low-maintenance convection cooling assures quiet and trouble-free operation.

        An override feature allows each channel to be adjusted to a preset state during setup. In the event that Cresnet communications should be disrupted for any reason, a simple contact closure can be used to activate the override presets on a global or semi-global basis.

        The CLX-2DIM2 occupies a single module space in any CAEN automation enclosure. Termination of high-voltage wiring to the module is facilitated by a CLT-2DIM2 terminal block, sold separately to enable termination of the wiring anytime prior to installing the module. CLX modules are controlled by the PAC2 and PAC2M professional automation control systems via the Cresnet network. A 5-wire link provides bussing of the Cresnet and override signals between modules within an enclosure (interconnect jumpers included).

         
        Key Features
        • CEC Title 24 2013 Compliant
         
        CrestronHome
        Load Ratings
          Dimmer Channels 2
          Per Channel 16 Amps (1920 Watts)
          Module Total 32 Amps (3840 Watts)
          Load Types Incandescent, Magnetic Low-voltage, Neon/Cold Cathode, Dimmable 2-Wire Fluorescent
        Power Requirements
          120 Volts AC, 50/60Hz, single-phase;
        All feeds must be same phase or split phase
        Connectors on Module
          Module Interconnect (2) 5-pin 0.156 inch headers;
        Cresnet/Override interconnect ports;
        Connect to PAC2, PAC2M, CAEN-BLOCK, or adjacent CLX-Series module using interconnect cable provided
        Connections via CLT Terminal Block (sold separately)
          LINE 1 - 2 (2) DIN rail terminal blocks, black, line power inputs;
        Must be same phase or split phase
          DIM 1 - 2 (2) DIN rail terminal blocks, red, channel outputs
          N IN 1 - 2 (2) DIN rail terminal blocks, white, line input neutrals
          N OUT 1 - 2 (2) DIN rail terminal blocks, white, channel output neutrals
        Buttons
          SETUP Used for manual channel activation and TSID
        LED Indicators
          PWR (green) Indicates line power is applied to the LINE terminal
          NET (yellow) Indicates communication with the control system
          1 – 2 (red x2) Indicates state of each channel
          SETUP (red) Indicates unit is in setup/manual mode
        Environmental
          Temperature 32° to 104°F (0° to 40°C)
          Humidity 10% to 90% RH (non-condensing)
          Heat Dissipation 20 BTU/Hr + (4.7 BTU/Hr x Load Current in Amps), 170 BTU/Hr at maximum load
        Enclosure
          Gray metal with black heat sink, surface mount module with (2) integral mounting flanges;
        Occupies 1 module space in any CAEN enclosure
        Dimensions
          Height 7.59 in (19.27 cm)
          Width 6.92 in (17.57 cm)
          Depth 3.43 in (8.70 cm)
        Weight
          3.00 lb (1.36 kg)
        Standards & Certifications
          CEC Title 24 2013 Compliant
        Click here to search product certificates.
        Pricing Region Select
        Please select your region below to see the appropriate Advertised Pricing.
        Powered by Translations.com GlobalLink OneLink SoftwarePowered By OneLink